EAST BEST GROUP (HK) CO., LIMITED.
PRODUCTSCurrent location :HOME > PRODUCTS > Central Inverter
SG2500HV-MV/SG3000HV-MV
  • SG2500HV-MV/SG3000HV-MV
SG2500HV-MV/SG3000HV-MV
【Brief】:

Sales Area Southern Africa Asia Pacific Europe and the Middle EastSouth America

 High Yield
  • Efficient three-level topology, max. inverterefficiency up to 99 %
  • 1 or 2 MPPT, wide MPP voltage range
  • Full power operation without derating at 50 ℃
  • One inverter unit fails, the other unit continues operation
 Easy O&M
  • Integrated zone current monitoring function for fast trouble shooting
  • Module design and front service, easy for maintenance
  • DC circuit breaker design for convenient maintenance
 Saved Investment
  • DC 1500 V system, low system initial investment
  • 20-foot container design, no need to build extra inverter house
  • Integrated MV transformer and LV auxiliary power supply
 Grid Support
  • Compliance with standards: CE, IEC 62109
  • Low/High voltage ride through (L/HVRT)
  • Active & reactive power control and power ramp rate control
【Series】:Central Inverter
Description

Technical Data

Input (DC) SG2500HV-MV SG3000HV-MV
Max. PV input voltage 1500 V
Min. PV input voltage / Startup input voltage 800 V / 840 V 900 V / 940 V
MPP voltage range for nominal power 800 – 1300 V 900 – 1300 V
No. of independent MPP inputs 1 or 2
No. of DC inputs 16 – 24
Max. PV input current 3508 A
Max. DC short-circuit current 4210 A
Output (AC)
Nominal AC power 2500 kW (at 50 ˚C) 3000 kW (at 50 ˚C)
Max. AC output at PF=1 2750 kW (at 45 ˚C) 3000 kW (at 50 ˚C)
Max. AC apparent power 2750 kVA (at 45 ˚C) 3000 kVA (at 50 ˚C)
Max. inverter output current 2886 A
AC voltage range 10 – 35 kV
Nominal grid frequency / Grid frequency 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz
THD < 3 % (at nominal power)
DC current injection < 0.5 % In
Power factor at nominal power / Adjustable > 0.99 / 0.8 leading – 0.8 lagging
Feed-in phases / Connection phases 3 / 3
Efficiency
Inverter max. efficiency / Inverter Euro efficiency 99.0 % / 98.7 %
Transformer
Transformer rated power 2500 kVA 3000 kVA
Transformer Max.power 2750 kVA 3000 kVA
LV / MV Voltage 0.55 kv / 10 – 35 kv 0.6 kV / 10 – 35 kV
Transformer Vector Dy11
Oil type Mineral oil (PCB free),or degradable oil on request
Protection
DC reverse connection protection Yes
DC input protection Circuit breaker
Inverter output protection Circuit breaker
AC output protection Circuit breaker * / Load switch + fuse **
Overvoltage protection DC Type II / AC Type II
Grid monitoring / Ground fault monitoring Yes / Yes
Insulation monitoring Yes
Overheat protection Yes
Anti-PID function Optional
General Data
Dimensions (W*H*D) 6058*2896*2438 mm
Weight 17 T
Degree of protection IP54
Auxiliary power supply 220 Vac, 2 kVA / Optional: 380 Vac, up to 15 kVA
Operating ambient temperature range -35 to 60 ℃ (> 50 ℃ derating)
Allowable relative humidity range (non-condensing) 0 – 95 %
Cooling method Temperature controlled forced air cooling
Max. operating altitude 1000 m (standard) / > 1000 m (optional)
Display Touch screen
Communication Standard: RS485, Ethernet; Optional: Optical fiber
Compliance CE, IEC 62109
Grid support LVRT, HVRT, active & reactive power control and power ramp rate control
Type designation SG2500HV-MV-S-10/SG2500HV-MV-C-10 SG3000HV-MV-S-10/SG3000HV-MV-C-10
*:available for SG2500HV-MV-S-10/SG3000HV-MV-S-10
**:available for SG2500HV-MV-C-10/SG3000HV-MV-C-10