- SG2500HV/SG3000HV
- 【Brief】:
Sales Area Southern Africa Asia Pacific Europe and the Middle East South America
High Yield
- Efficient three-level topology, max. inverterefficiency up to 99 %
- 1 or 2 MPPT, wide MPP voltage range
- Full power operation without derating at 50 ℃
- One inverter unit fails, the other unit continuesoperation
Easy O&M
- Integrated zone current monitoring function forfast trouble shooting
- Module design and front service, easy formaintenance
- DC circuit breaker design for convenientmaintenance
Saved Investment
- DC 1500 V system, low system initial investment
- 10-foot container design, no need to build extrainverter house
- Integrated LV auxiliary power supply
Grid Support
- Compliance with standards: IEC 62109, IEC61727, IEC 62116, CE, G59/3
- Low/High voltage ride through (L/HVRT)
- Active & reactive power control and powerramp rate control
- 【Series】:Central Inverter
- Description
Technical Data
Input (DC) SG2500HV-MV SG3000HV-MV Max. PV input voltage 1500 V Min. PV input voltage / Startup input voltage 800 V / 840 V 900 V / 940 V MPP voltage range for nominal power 800 – 1300 V 900 – 1300 V No. of independent MPP inputs 1 or 2 No. of DC inputs 16 – 24 Max. PV input current 3508 A Max. DC short-circuit current 4210 A Output (AC) Nominal AC power 2500 kW (at 50 ˚C) 3000 kW (at 50 ˚C) Max. AC output at PF=1 2750 kW (at 45 ˚C) 3000 kW (at 50 ˚C) Max. AC apparent power 2750 kVA (at 45 ˚C) 3000 kVA (at 50 ˚C) Max. inverter output current 2886 A Nominal AC voltage 550 V 600 V AC voltage range 440 – 632 V 480 – 690 V Nominal grid frequency / Grid frequency range 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz THD < 3 % (at nominal power) DC current injection < 0.5 % In Power factor at nominal power / Adjustable power factor > 0.99 / 0.8 leading – 0.8 lagging Feed-in phases / Connection phases 3 / 3 Efficiency Inverter max. efficiency / Inverter Euro efficiency 99.0 % / 98.7 % Protection DC reverse connection protection Yes DC input protection Circuit breaker AC output protection Circuit breaker Overvoltage protection DC Type II / AC Type II Grid monitoring / Ground fault monitoring Yes / Yes Insulation monitoring Yes Overheat protection Yes Anti-PID function Optional General Data Dimensions (W*H*D) 2991*2591*2438 mm Weight 5.9 T Isolation method Transformerless Degree of protection IP54 Auxiliary power supply 220 Vac, 2 kVA / Optional: 380 Vac, up to 15 kVA Operating ambient temperature range -35 to 60 ℃ (> 50 ℃ derating) Allowable relative humidity range (non-condensing) 0 - 95 % Cooling method Temperature controlled forced air cooling Max. operating altitude 4500 m (> 3500 m derating) 4000 m (> 2000 m derating) Display Touch screen Communication Standard: RS485, Ethernet; Optional: Optical fiber Compliance CEA, IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683, CE, G59/3 Grid support LVRT, HVRT, active & reactive power control and power ramp rate control Type designation SG2500HV-10 SG3000HV-10