- SG2000-MV/SG2500-MV
- 【Brief】:
Sales Area Asia Pacific Europe and the Middle East Japan South America
High Yield
- Efficient three-level topology, max. inverterefficiency up to 99 %
- 1 or 4 MPPT, wide MPP voltage range
- Full power operation without derating at 50 ℃
- One inverter unit fails, the other unit continuesoperation
Easy O&M
- Integrated zone current monitoring function for fast trouble shooting
- Module design and front service, easy for maintenance
- DC circuit breaker design for convenient maintenance
Saved Investment
- 20-foot container design, no need to build extra inverter house
- Integrated MV transformer and LV auxiliary power supply
Grid Support
- Compliance with standards: CE, IEC 62109
- Low/High voltage ride through (L/HVRT)
- Active & reactive power control and power ramp rate control
- 【Series】:Central Inverter
- Description
Technical Data
Input (DC) SG2000-MV SG2500-MV Max. PV input voltage 1000 V Min. PV input voltage / Startup input voltage 460 V / 500 V 520 V / 540 V MPP voltage range for nominal power 460 – 850 V 520 – 850 V No. of independent MPP inputs 1 or 4 No. of DC inputs 16 – 32 Max. PV input current 4880 A 5424 A Max. DC short-circuit current 5840 A 6780 A Output (AC) Nominal AC power (at 55 ˚C) 2000 kW 2520 kW Max. AC output at PF=1 (at 45 ˚C) 2200 kW 2772 kW Max. AC apparent power (at 45 ˚C) 2200 kVA 2772 kVA Max. inverter output current 4032 A 4444 A AC voltage range 10 – 35 kV Nominal grid frequency / Grid frequency 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz THD < 3 % (at nominal power) DC current injection < 0.5 % In Power factor at nominal power / Adjustable power factor > 0.99 / 0.8 leading – 0.8 lagging Feed-in phases / Connection phases 3 / 3 Efficiency Inverter max. efficiency / Inverter Euro efficiency 99.0 % / 98.7 % Transformer Transformer rated power 2000 kVA 2520 kVA Transformer Max.power 2200 kVA 2772 kVA LV / MV volatage 0.315 kV / 10 – 35 kV 0.360 kV / 10 – 35 kV Transformer Vector Dy11 Oil type Mineral oil (PCB free) or degradable oil on request Protection DC reverse connection protection Yes DC input protection Circuit breaker Inverter output protection Circuit breaker AC output protection Circuit breaker * / Load switch + fuse ** Overvoltage protection DC Type II / AC Type II Grid monitoring / Ground fault monitoring Yes / Yes Insulation monitoring Yes Overheat protection Yes Anti-PID function Optional General Data Dimensions (W*H*D) 6058*2896*2438 mm Weight 17 T Degree of protection IP54 Auxiliary power supply 220 Vac, 2 kVA / Optional: 380 Vac, up to 15 kVA Operating ambient temperature range -35 to 60 ℃ (> 50 ℃ derating) Allowable relative humidity range (non-condensing) 0 - 95 % Cooling method Temperature controlled forced air cooling Max. operating altitude 1000 m (standard) / > 1000 m (optional) Display Touch screen Communication Standard: RS485, Ethernet; Optional: Optical fiber Compliance CE, IEC 62109 Grid support LVRT, HVRT, active & reactive power control and power ramp rate control Type designation SG2000-MV-S-10/SG2000-MV-C-10 SG2500-MV-S-10/SG2500-MV-C-10 *:available for SG20000-MV-S-10/SG2500-MV-S-10
**:available for SG2000-MV-C-10/SG2500-MV-C-10
Pre:SG2000/SG2500
Next:SG1000MX