- SG33KTL-M/SG36KTL-M
- 【Brief】:
Sales Area Southern Africa Asia Pacific Europe and the Middle East India and Sri Lanka South America
High Yield
- Max. efficiency 98.5 %, European efficiency 98.3 %
- Long-term overload at 1.1 Pn (SG33KTL-M)
- Full power operation without derating at 50 ℃ Up to 3 MPP trackers
Easy O&M
- Integrated string current monitoring function for fast trouble shooting
- Compact design and light weight for easy installation
- Plug-in design of fan and SPD, easy for on-site maintenance
Saved Investment
- Max. DC/AC ratio up to 1.4
- Can be installed horizontally, saving installation cost
- Integrated DC combiner box and DC/AC overvoltage protection
Grid Support
- Compliance with standards: CE, IEC 62109, IEC 61727, IEC 62116, VDE 0126-1-1, VDEAR-N-4105
- Low/High voltage ride through (L/HVRT)
- Active & reactive power control and power ramp rate control
- 【Series】:String Inverter
- Description
Technical Data
Input (DC) SG33KTL-M SG36KTL-M Max. PV input voltage 1100 V Min. PV input voltage / Startup input voltage 200 V / 250 V Nominal input voltage 585 V MPP voltage range 200 – 1000 V MPP voltage range for nominal power 500 – 850 V No. of independent MPP inputs 3 Max. number of PV strings per MPPT 3 / 3 / 2 Max. PV input current 88 A (33 A / 33 A / 22 A) Max. current for input connector 12 A Max. DC short-circuit current 96 A (36 A / 36 A / 24 A) Output (AC) Nominal AC power (at 50 ˚C) 33000 W 36000 W Max. AC output at PF=1 (at 45 ˚C) 36000 W Max. AC apparent power (at 45 ˚C) 36000 VA Max. AC output current 53.5 A Nominal AC voltage 3 / PE or 3 / N / PE, 230 / 400 V AC voltaye range 310 – 480 V Nominal grid frequency / Grid frequency range 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz THD < 3 % (at nominal power) DC current injection < 0.5 % In Power factor at nominal powe / Adjustable power factor > 0.99 / 0.8 leading – 0.8 lagging Feed-in phases / Connection phases 3 / 3 Efficiency Max. efficiency / Euro. efficiency 98.5 % / 98.3 % Protection DC reverse connection protection Yes AC short-circuit protection Yes Leakage current protection Yes Grid monitoring Yes DC switch / AC switch Yes / No DC fuse Yes (positive, 15A) PV string current monitoring Yes Overvoltage protection DC Type II / AC Type II General Data Dimensions (W*H*D) 525*740*240 mm Weight 48 kg Isolation method Transformerless Degree of protection IP65 Night power consumption < 2 W Operating ambient temperature range -25 to 60 ℃ (> 50 ℃ derating) Allowable relative humidity range (non-condensing) 0 – 100% Cooling method Smart forced air cooling Max. operating altitude 4000 m (> 3000 m derating) Display / Communication Graphic LCD / RS485 DC connection type MC4 (Max. 6 mm² ) AC connection type Screw clamp terminal (Max. 50 mm² ) Compliance CEA, IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683, CE, IEC 61000-3-11/-12, VDE 0126-1-1, VDE-AR-N-4105 Grid support LVRT, HVRT, active & reactive power control and power ramp rate control Type designation SG33KTL-M-10 SG36KTL-M-10
Pre:SG30KU
Next:SG50KTL-M